مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,726
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

OPTIMIZATION OF TREATMENT PARAMETERS FOR POST MASTECTOMY ELECTRON THERAPY OF DEFECTED CHEST-WALL

Pages

  547-554

Abstract

 Background: ELECTRONs have an advantage of steep dose fall-off after R80. The unique curved geometry of the chest-wall and the special isodose shapes of ELECTRONs make complexities to chest-wall ELECTRON therapy. BOLUS material has been applied to ELECTRON fields for shaping the coverage of planned volume and compensating for surface irregularities. ELECTRON BOLUS conformal therapy methods are not yet vastly available; therefore, this study tries to extrapolate suggestions for conventional usage of BOLUS and different ELECTRON beam energies.Methods: Computer plans for 10 post-mastectomy patients with at least 1cm elevated or depressed surgical defects were designed. BOLUS thicknesses of 5, 10, and 15 mm and ELECTRON energies of 9, 12, 15, and 18 MeV were applied to the clinical target volume. Average doses to the surface, clinical target volume (CTV1), ipsilateral lung and heart were calculated by the planning system and then analyzed.Findings: High energies of ELECTRONs and thicker BOLUS reduced the risk of CTV1 underdose. BOLUS increases surface dose whereas decreases mean dose to CTV. Nine MeV ELECTRONs and BOLUS was unsuitable for this type of treatment. In most treatments the dose increase to lung was statistically significant (P<0.01) with higher energies of ELECTRONs and lower thicknesses of BOLUS. This was not observed for the heart.Conclusion: Careful design of BOLUS thickness is important when planning with lower energy ELECTRONs. This study suggests that planning with thicker BOLUS material and higher energy selection has advantage of dose conformity with conventional methods of ELECTRON therapy in a defected surface.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MAHDAVI, HODA, JABBARI, KEYVAN, & ROAYAEI, MAHNAZ. (2016). OPTIMIZATION OF TREATMENT PARAMETERS FOR POST MASTECTOMY ELECTRON THERAPY OF DEFECTED CHEST-WALL. JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), 34(383), 547-554. SID. https://sid.ir/paper/51207/en

    Vancouver: Copy

    MAHDAVI HODA, JABBARI KEYVAN, ROAYAEI MAHNAZ. OPTIMIZATION OF TREATMENT PARAMETERS FOR POST MASTECTOMY ELECTRON THERAPY OF DEFECTED CHEST-WALL. JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S)[Internet]. 2016;34(383):547-554. Available from: https://sid.ir/paper/51207/en

    IEEE: Copy

    HODA MAHDAVI, KEYVAN JABBARI, and MAHNAZ ROAYAEI, “OPTIMIZATION OF TREATMENT PARAMETERS FOR POST MASTECTOMY ELECTRON THERAPY OF DEFECTED CHEST-WALL,” JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), vol. 34, no. 383, pp. 547–554, 2016, [Online]. Available: https://sid.ir/paper/51207/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button