مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

364
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

116
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON BETWEEN CLASSIC LARYNGEAL MASK AND COBRA PERILARYNGEAL AIRWAY DURING MECHANICAL VENTILATION

Pages

  13-19

Abstract

 Background: Selection of an optimal method for the safe preoperative airway management is the base of a successful GENERAL ANESTHESIA. To achieve this goal various methods and devices are used including end tracheal tube and LARYNGEAL MASK airway, each has its own advantages and disadvantages. In this study, we compared a new supraglottic instrument (COBRA PERILARYNGEAL AIRWAY) with LARYNGEAL MASK airway (LMA), considering each one's abilities specially their role in preventing intraocular pressure rise during insertion.Materials and Methods: In a prospective randomized clinical trial 200 ASA class l. ll patients with no history of glaucoma, cardiovascular or respiratory diseases and susceptibility to difficult intubation were randomly divided into two similar groups (100 subjects each). None of them (age range 6-70 yrs) received premedication after preoxygenation and induction with sodium thiopental, fentanyl and atracurium. The patient was ventilated manually then one of the devices was inserted. After assurance of the correct position, its cuff was filled with air. In this study various factors including intraocular pressure (lOP), systolic blood pressure (SBP), SPO2, end tidal CO2 (ETCO2), heart rate, peak airway pressure and end expiratory tidal volume were recorded exactly before the induction (time 1), after the induction (time 2), 5 minutes after the induction (time 3), 15 minutes after the induction (time 4), and 5 minutes after releasing the device (time 5). Cuff pressure was measured immediately after insertion and at the end of operation.Quality of insertion (1: simple 2: relatively simple 3: difficult 4: unsuccessful), their complications (bleeding, no bleeding) and sore throat 2 and 24 hours after the operation were detected by interview. Fitness of LMA or Cobra PLA on airway for prevention of air leakage was recorded as well. Qualitative data with chi-square and quantitative data with t-test and SPSS software (version 11) were analyzed.Results: There was no clinical significant difference between the two groups regarding age, sex, ASA class, weight, and duration of surgery, SPO2, heart rate and blood pressure. Cobra PLA offered advantages in regard to easy insertion (p=0.005), sore throat (p<0.0001) and bleeding (p<0.0001). Mean rise of intraocular pressure and mean increase of systolic blood pressure (at the time 3) was higher in LMA (p=0.02). Regarding ETCO2 (p=0.0001), peak airway pressure (p<0.0001), ability to fitness on airway (p=0.01) and cuff pressure (p<0.0001) cobra significantly offered advantages over LMA. Conclusion: Cobra PLA is a useful device for airway management in GENERAL ANESTHESIA during MECHANICAL VENTILATION with minimal post-up complication and simplicity of usage offering high potential ventilation. More studies are required in regard to use of Cobra tube in different ages.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    AGAH, M., YAHYAVI, P., & ROUDNESHIN, F.. (2006). COMPARISON BETWEEN CLASSIC LARYNGEAL MASK AND COBRA PERILARYNGEAL AIRWAY DURING MECHANICAL VENTILATION . TANAFFOS, 5(2 (18)), 13-19. SID. https://sid.ir/paper/538612/en

    Vancouver: Copy

    AGAH M., YAHYAVI P., ROUDNESHIN F.. COMPARISON BETWEEN CLASSIC LARYNGEAL MASK AND COBRA PERILARYNGEAL AIRWAY DURING MECHANICAL VENTILATION . TANAFFOS[Internet]. 2006;5(2 (18)):13-19. Available from: https://sid.ir/paper/538612/en

    IEEE: Copy

    M. AGAH, P. YAHYAVI, and F. ROUDNESHIN, “COMPARISON BETWEEN CLASSIC LARYNGEAL MASK AND COBRA PERILARYNGEAL AIRWAY DURING MECHANICAL VENTILATION ,” TANAFFOS, vol. 5, no. 2 (18), pp. 13–19, 2006, [Online]. Available: https://sid.ir/paper/538612/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button