Title

COMPARISON OF CENTRAL CORNEAL THICKNESS MEASUREMENTS WITH PENTACAM, ORBSCAN II, AND ULTRASOUND PACHYMETER

Pages

  51-57

Abstract

 Purpose: To compare thickness of central cornea measured using PENTACAM, ORBSCAN II, and ULTRASOUND pachymeter.Methods: Patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. CENTRAL CORNEAL THICKNESS (CCT) was measured by three methods using PENTACAM, ORBSCAN II, and ULTRASOUND pachymeter.Results: Comparison of ULTRASOUND and ORBSCAN CCT measurements showed a relatively high correlation between these two devices (P<0.001; r=0.891). The 95% limits of AGREEMENT (LoA) between these two devices were -42.44 to 20.18 mm. There was also a high correlation between the results obtained through ULTRASOUND and PENTACAM (P<0.001; r=0.932). The 95% LoA of CCT with ULTRASOUND and PENTACAM were -13.35 to 24.16 mm. There was also a high correlation between CCT measurements carried out by ORBSCAN and PENTACAM (P<0.001) and the 95% LoA were -12.14 to 45.19 mm.Conclusion: The findings of the present study demonstrated high AGREEMENTs between the CCT readings measured with ORBSCAN, PENTACAM, and ULTRASOUND. The AGREEMENT between the PENTACAM and ULTRASOUND measurements was higher than that of between ORBSCAN and ULTRASOUND, making PENTACAM a better substitute for ULTRASOUND.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    YEKTA, A.A., HASHEMI, HASAN, KHABAZ KHOUB, MAHDI, DOUSTDAR, A., MEHRAVARAN, SH., HERAVIAN SHANDIZ, J., & FOTOUHI, AKBAR. (2009). COMPARISON OF CENTRAL CORNEAL THICKNESS MEASUREMENTS WITH PENTACAM, ORBSCAN II, AND ULTRASOUND PACHYMETER. JOURNAL OF CURRENT OPHTHALMOLOGY, 21(2), 51-57. SID. https://sid.ir/paper/562794/en

    Vancouver: Copy

    YEKTA A.A., HASHEMI HASAN, KHABAZ KHOUB MAHDI, DOUSTDAR A., MEHRAVARAN SH., HERAVIAN SHANDIZ J., FOTOUHI AKBAR. COMPARISON OF CENTRAL CORNEAL THICKNESS MEASUREMENTS WITH PENTACAM, ORBSCAN II, AND ULTRASOUND PACHYMETER. JOURNAL OF CURRENT OPHTHALMOLOGY[Internet]. 2009;21(2):51-57. Available from: https://sid.ir/paper/562794/en

    IEEE: Copy

    A.A. YEKTA, HASAN HASHEMI, MAHDI KHABAZ KHOUB, A. DOUSTDAR, SH. MEHRAVARAN, J. HERAVIAN SHANDIZ, and AKBAR FOTOUHI, “COMPARISON OF CENTRAL CORNEAL THICKNESS MEASUREMENTS WITH PENTACAM, ORBSCAN II, AND ULTRASOUND PACHYMETER,” JOURNAL OF CURRENT OPHTHALMOLOGY, vol. 21, no. 2, pp. 51–57, 2009, [Online]. Available: https://sid.ir/paper/562794/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button