مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

527
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

7

Information Journal Paper

Title

DISPERSIVE LIQUID-LIQUID MICROEXTRACTION BASED ON SOLIDIFICATION OF FLOATING ORGANIC DROP COMBINED WITH FLAME ATOMIC ABSORPTION SPECTROMETRY FOR PRECONCENTRATION AND DETERMINATION OF THALLIUM(III) IN WATER SAMPLES

Pages

  59-66

Keywords

THALLIUM (III) 
DISPERSIVE LIQUID-LIQUID MICROEXTRACTION TECHNIQUE BASED ON SOLIDIFICATION OF A FLOATING ORGANIC DROP (DLLME-SFO) 

Abstract

 Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with FLAME ATOMIC ABSORPTION SPECTROMETRY was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4-which forms an ion pair with BRILLIANT GREEN reagent and as a result a cloudy mixture was formed. After centrifugation, the test tube was cooled for 5 min and the solidified 1-undecanol drop formed on the top of the solution was transferred into a suitable vial and it was dissolved in 300μL of acetone and finally introduced into the flame atomic absorption spectrometer. Several factors affecting the extraction process, such as the volume of the extractant and disperser solvents, centrifugation time, concentration of BRILLIANT GREEN, concentration of HCl, ionic strength, volume of diluting solvent and interferences were studied. Under the optimum operating conditions, the calibration graph was linear in the range of 240-6000ng/mL with a limit of detection of 90 ng/mL and preconcentration factor was 17.The Relative Standard Deviation (RSD) for five replicate measurements of thallium was 3.6%.The accuracy of the method was assessed using a certified reference material (unalloyed zinc) and spiked tap water. The results demonstrated high accuracy, recovery and applicability of the presented method.

Cites

References

  • No record.
  • Cite

    APA: Copy

    CHAMSAZ, MAHMOUD, HOSSEIN POOR ZARYABI, MOHADESE, ARBAB ZAVAR, MOHAMMAD HOSSEIN, & DARROUDI, ABOLFAZL. (2014). DISPERSIVE LIQUID-LIQUID MICROEXTRACTION BASED ON SOLIDIFICATION OF FLOATING ORGANIC DROP COMBINED WITH FLAME ATOMIC ABSORPTION SPECTROMETRY FOR PRECONCENTRATION AND DETERMINATION OF THALLIUM(III) IN WATER SAMPLES. IRANIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING (IJCCE), 33(1), 59-66. SID. https://sid.ir/paper/646607/en

    Vancouver: Copy

    CHAMSAZ MAHMOUD, HOSSEIN POOR ZARYABI MOHADESE, ARBAB ZAVAR MOHAMMAD HOSSEIN, DARROUDI ABOLFAZL. DISPERSIVE LIQUID-LIQUID MICROEXTRACTION BASED ON SOLIDIFICATION OF FLOATING ORGANIC DROP COMBINED WITH FLAME ATOMIC ABSORPTION SPECTROMETRY FOR PRECONCENTRATION AND DETERMINATION OF THALLIUM(III) IN WATER SAMPLES. IRANIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING (IJCCE)[Internet]. 2014;33(1):59-66. Available from: https://sid.ir/paper/646607/en

    IEEE: Copy

    MAHMOUD CHAMSAZ, MOHADESE HOSSEIN POOR ZARYABI, MOHAMMAD HOSSEIN ARBAB ZAVAR, and ABOLFAZL DARROUDI, “DISPERSIVE LIQUID-LIQUID MICROEXTRACTION BASED ON SOLIDIFICATION OF FLOATING ORGANIC DROP COMBINED WITH FLAME ATOMIC ABSORPTION SPECTROMETRY FOR PRECONCENTRATION AND DETERMINATION OF THALLIUM(III) IN WATER SAMPLES,” IRANIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING (IJCCE), vol. 33, no. 1, pp. 59–66, 2014, [Online]. Available: https://sid.ir/paper/646607/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
    File Not Exists.
    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button