مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

249
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

150
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE EFFECTS OF DENTURE CLEANSING SOLUTIONS ON THE RETENTION OF ATTACHMENTS OF IMPLANT SUPPORTED OVERDENTURES

Pages

  68-72

Abstract

 Statement of the Problem: Implant-retained overdenture can improve the stability of dentures and prevent bone loss. Overdenture-wearing patients need special hygiene care.Purpose: The aim of this study was to evaluate the effects of various DENTURE CLEANSERs on the retention of Dio orange O-rings.Method and Materials: In this experimental study, 40 Dio orange O-rings were divided into 4 groups (10 O-rings each) and each group was soaked for equivalent of 6 months in the following solutions: 5.25% NaOCl (1:10 dilution), Corega cleanser tabs, Professional cleanser tabs and water (as the control group). After 6 months, O-rings were tested for 2inch/minutes of tensile force. The peak load-todislodgement was recorded. Data were imported to SPSS18 and were analyzed by One-Way ANOVA and Tukey HSD test (p≤0.05).Results: Denture cleansing solutions have significant effects on the reduction of retentive value of O-rings (p≤ 0.001). Corega tabs caused the reduction of 15.7% (9.91±0.53 N) in the retentive value of O-rings and Professional tabs caused 15% (10.00±0.86 N). NaOCl caused significant decrease (48%) in retentive value of O-rings (6.10±0.91 N in comparison with the control group (11.76±1 N).Conclusion: This in-vitro study demonstrated that the retention of O-rings was affected when soaked in cleansing solutions. NaOCl caused more reduction in retentive value compared to effervescent cleansers and would not be recommended for cleansing O-rings. These results should be interpreted clinically and the role of other factors in the retention of O-rings should be considered in order to recommend the best cleanser for O-ring overdentures.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    DERAFSHI, REZA, MOHAGHEGH, MINA, SAKI, MARYAM, SAFARI, ANAHITA, & RABEE HAGHIGHI, MOHAMMAD. (2015). THE EFFECTS OF DENTURE CLEANSING SOLUTIONS ON THE RETENTION OF ATTACHMENTS OF IMPLANT SUPPORTED OVERDENTURES. JOURNAL OF DENTISTRY (SHIRAZ UNIVERSITY OF MEDICAL SCIENCES), 16(SUPPLEMENT (1)), 68-72. SID. https://sid.ir/paper/660771/en

    Vancouver: Copy

    DERAFSHI REZA, MOHAGHEGH MINA, SAKI MARYAM, SAFARI ANAHITA, RABEE HAGHIGHI MOHAMMAD. THE EFFECTS OF DENTURE CLEANSING SOLUTIONS ON THE RETENTION OF ATTACHMENTS OF IMPLANT SUPPORTED OVERDENTURES. JOURNAL OF DENTISTRY (SHIRAZ UNIVERSITY OF MEDICAL SCIENCES)[Internet]. 2015;16(SUPPLEMENT (1)):68-72. Available from: https://sid.ir/paper/660771/en

    IEEE: Copy

    REZA DERAFSHI, MINA MOHAGHEGH, MARYAM SAKI, ANAHITA SAFARI, and MOHAMMAD RABEE HAGHIGHI, “THE EFFECTS OF DENTURE CLEANSING SOLUTIONS ON THE RETENTION OF ATTACHMENTS OF IMPLANT SUPPORTED OVERDENTURES,” JOURNAL OF DENTISTRY (SHIRAZ UNIVERSITY OF MEDICAL SCIENCES), vol. 16, no. SUPPLEMENT (1), pp. 68–72, 2015, [Online]. Available: https://sid.ir/paper/660771/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button