Title

Determining Factors Affecting Fire Risk in a Hospital in Qazvin, Iran

Pages

  115-122

Keywords

Fire risk assessment method for engineering (FRAME) 

Abstract

 Background: Hospitals are highly vulnerable to Fire because of the presence of vulnerable people (patients, medical staff, and visitors), expensive equipment, and the ignorance and lowrisk perception of occupants. Injuries caused by Fire can result in life and financial losses and can disrupt the performance of a Hospital. Fire Risk assessment is an effective way to assess vulnerability, capacity, and capability. This study aims to evaluate the risk of Fire and identify the effective factors and their contribution to a Hospital. Materials and Methods: This cross-sectional study was conducted using the Fire Risk assessment Method for Engineering (FRAME) in the equipment room of a Hospital in Qazvin, Iran. The Fire risk was first calculated by using the related formulas in Excel software. Then, the influential factors and their contribution to the overall risk were determined to perform corrective measures for reducing the risk. Results: The numerical value of risk for the building and its contents, occupants, and activities were 2. 075, 3. 315, and 2. 481, respectively (>1), indicating its unacceptable level. Factors affecting the potential risk level for the building and its content and occupants were Fire load, venting, and access. Regarding the acceptable risk level, the activation factor was identified as an influential factor in all domains. The highest contribution in the potential risk level for the building and its content and occupants was related to the Fire load factor (1. 6). In the acceptable risk level, the highest contribution was related to the activation factor (0. 4). Conclusion: The FRAME method can also identify effective factors and their contribution to the overall Fire risk of medical centers such as Hospitals to help develop plans and special measures to reduce the risk.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    Kurd, Hazhir, ZAROUSHANI, VIDA, AKBARI, YOUSEF, & SAFARI VARIANI, ALI. (2021). Determining Factors Affecting Fire Risk in a Hospital in Qazvin, Iran. HEALTH IN EMERGENCIES AND DISASTERS QURTERLY, 6(2), 115-122. SID. https://sid.ir/paper/689542/en

    Vancouver: Copy

    Kurd Hazhir, ZAROUSHANI VIDA, AKBARI YOUSEF, SAFARI VARIANI ALI. Determining Factors Affecting Fire Risk in a Hospital in Qazvin, Iran. HEALTH IN EMERGENCIES AND DISASTERS QURTERLY[Internet]. 2021;6(2):115-122. Available from: https://sid.ir/paper/689542/en

    IEEE: Copy

    Hazhir Kurd, VIDA ZAROUSHANI, YOUSEF AKBARI, and ALI SAFARI VARIANI, “Determining Factors Affecting Fire Risk in a Hospital in Qazvin, Iran,” HEALTH IN EMERGENCIES AND DISASTERS QURTERLY, vol. 6, no. 2, pp. 115–122, 2021, [Online]. Available: https://sid.ir/paper/689542/en