مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,014
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DOSIMETRY, CONTROL AND IRRADIATION OF RAT CERVICAL SPINAL CORD

Pages

  7-13

Abstract

 BACKGROUND AND OBJECTIVE: In RADIOBIOLOGY, the most important physical radiation quantity to predict the effect of irradiation of a biological specimen is the absorbed dose to the tissue of interest. In this project an irradiation set up was designed and verification of set up and dosimetry procedure was performed to deliver a precise X-ray dose to the small field of rat cervical spinal cord.METHODS: AAPM-TG61 (American association & physician in medicine radiation therapy committee task group 61) protocol was used for dose measurement and we tailored a rat like phantom from polyethylene for dosimetry verification. The ionization chamber in this study was a farmer type and the X-ray generator was an orthovoltage Siemens machine working at 200 KVp potential. Dosimetry was done in air and phantom. An special JIG was also built to fix the animals during irradiation which could help the treatments to be reproducible. Simulation and portal films were obtained to verify the irradiation field.FINDINGS: The average value of dose rate in specified geometries by measurement was 146.54 cGy/min (SD= 0.109). While the dose determined by calculation was 95.145 cGy/min (SD= 0.105), the comparison between these two methods shown a small discrepancy of 0.50% (p<0.001), which lies within the error limit of ± 5.3% as mentioned by ICRU.CONCLUSION: Using protocol of AAPM TG-61 can provide an accurate dosimetry with minimum ambiguity. Application of appropriate correction factors and protocols can increase the accuracy and decrease the irradiation errors in radiobiological studies

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MAHDAVI, S.R., ZABIHZADEH, M., SHIRAZI, A., & GHARAATI, H.. (2005). DOSIMETRY, CONTROL AND IRRADIATION OF RAT CERVICAL SPINAL CORD . JOURNAL OF BABOL UNIVERSITY OF MEDICAL SCIENCES (JBUMS), 7(2 (26)), 7-13. SID. https://sid.ir/paper/73769/en

    Vancouver: Copy

    MAHDAVI S.R., ZABIHZADEH M., SHIRAZI A., GHARAATI H.. DOSIMETRY, CONTROL AND IRRADIATION OF RAT CERVICAL SPINAL CORD . JOURNAL OF BABOL UNIVERSITY OF MEDICAL SCIENCES (JBUMS)[Internet]. 2005;7(2 (26)):7-13. Available from: https://sid.ir/paper/73769/en

    IEEE: Copy

    S.R. MAHDAVI, M. ZABIHZADEH, A. SHIRAZI, and H. GHARAATI, “DOSIMETRY, CONTROL AND IRRADIATION OF RAT CERVICAL SPINAL CORD ,” JOURNAL OF BABOL UNIVERSITY OF MEDICAL SCIENCES (JBUMS), vol. 7, no. 2 (26), pp. 7–13, 2005, [Online]. Available: https://sid.ir/paper/73769/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button