Title

Distal Femoral Valgus Cut Errors in Total Knee Replacement (LETTER TO THE EDITOR)

Pages

  463-464

Keywords

Not Registered.

Abstract

 Dear Editor The causes of coronal malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides. We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement. Based on the literature, a marginal limit of 3 degrees of error in frontal joint line orientation angle is acceptable and will not affect prosthetic joint survival (2-4). Outliers are expected to encounter problems in terms of earlier loosening, more pain, wear and subsidence which may eventually result in revision. To achieve normal mechanical axis, the errors in distal femoral valgus cut should be given specific attention to be minimized. In regard with the recently published study data by Maurin Lampard et. al. applying fixed hip knee shaft angle for alignment of the distal cut leads to significant error in coronal TKA alignment because of great variability and asymmetry of distal femoral anatomy. Mont and Arquhart et. al showed that even experienced surgeons may make errors (50%>1 degree and 38%>2 degrees of error) and may need to recut. Navigation can help reducing the errors but recent studies showed that it is not flawless...

Cites

  • No record.
  • References

    Cite

    APA: Copy

    YAZDI, HAMID REZA, & Ghaderi, Mohammad Taher. (2020). Distal Femoral Valgus Cut Errors in Total Knee Replacement (LETTER TO THE EDITOR). THE ARCHIVES OF BONE AND JOINT SURGERY, 8(3), 463-464. SID. https://sid.ir/paper/755807/en

    Vancouver: Copy

    YAZDI HAMID REZA, Ghaderi Mohammad Taher. Distal Femoral Valgus Cut Errors in Total Knee Replacement (LETTER TO THE EDITOR). THE ARCHIVES OF BONE AND JOINT SURGERY[Internet]. 2020;8(3):463-464. Available from: https://sid.ir/paper/755807/en

    IEEE: Copy

    HAMID REZA YAZDI, and Mohammad Taher Ghaderi, “Distal Femoral Valgus Cut Errors in Total Knee Replacement (LETTER TO THE EDITOR),” THE ARCHIVES OF BONE AND JOINT SURGERY, vol. 8, no. 3, pp. 463–464, 2020, [Online]. Available: https://sid.ir/paper/755807/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button