Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

170
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

116
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A Simulation Study With Electronic Dosimeter to Estimate Patient and Personnel Dose in Orthopedic Surgery

Pages

  61-66

Abstract

 Background: The use of mini C-arm is required in many Orthopedic surgeries as an imageguided tool. Studies have shown an unnecessarily high dose to patients if Exposures are not properly optimized. Also, scatter radiation to Personnel may increase the risk of cancer if an appropriate Protective device is not used. Objectives: This study aims to determine the patient’ s dose and scatter radiation to the surgeon, anesthetist, and scrub nurse. Also, a comparison will be made with other studies on this topic. Methods: A phantom was designed to simulate a patient on the operating table to produce scatter radiation. In the same vein, a mobile mini C-arm unit was positioned with the x-ray tube beneath the head and the image receptor above the operating table. Measurements were made with a measuring tape from the central axis to the position of the surgeon, anesthetist, and scrub nurse. The Entrance surface dose (ESD) was determined by placing the electronic dosimeter at the surface of the phantom to estimate the patient dose. Similarly, each Personnel dose/dose rate from the central axis was determined using a similar detector. Results: The total average time for most Orthopedic surgeries in the studied facility was 3. 3 minutes. The estimated ESD to the patient was 25. 03 μ Sv and the scatter radiation per patient reaching the simulated anesthetist, scrub nurse, and surgeon was, 3. 75, 3. 59, and 7. 72 μ Sv, respectively. The estimated dose values per year to anesthetist, scrub nurse, and surgeon were 390, 373. 36, and 802 μ Sv, respectively. Conclusion: The Personnel recommended limit dose rate was <20000 μ Sv/y. The technical factor used and total Exposure time from this study could have affected the Radiation dose. This study showed that Personnel was safe even without the use of lead apron. Nevertheless, the use of an appropriate Protective device should be encouraged to ensure safety.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    Omojola, Akintayo, Akpochafor, Michael, & Adeneye, Samuel. (2020). A Simulation Study With Electronic Dosimeter to Estimate Patient and Personnel Dose in Orthopedic Surgery. JOURNAL OF RESEARCH IN ORTHOPEDIC SCIENCE (SHAFA ORTHOPEDIC JOURNAL), 7(2), 61-66. SID. https://sid.ir/paper/759525/en

    Vancouver: Copy

    Omojola Akintayo, Akpochafor Michael, Adeneye Samuel. A Simulation Study With Electronic Dosimeter to Estimate Patient and Personnel Dose in Orthopedic Surgery. JOURNAL OF RESEARCH IN ORTHOPEDIC SCIENCE (SHAFA ORTHOPEDIC JOURNAL)[Internet]. 2020;7(2):61-66. Available from: https://sid.ir/paper/759525/en

    IEEE: Copy

    Akintayo Omojola, Michael Akpochafor, and Samuel Adeneye, “A Simulation Study With Electronic Dosimeter to Estimate Patient and Personnel Dose in Orthopedic Surgery,” JOURNAL OF RESEARCH IN ORTHOPEDIC SCIENCE (SHAFA ORTHOPEDIC JOURNAL), vol. 7, no. 2, pp. 61–66, 2020, [Online]. Available: https://sid.ir/paper/759525/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top