مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

129
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

112
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Technical note: A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer

Pages

  185-189

Keywords

CI 
HI 

Abstract

 Background: The influence of the limit ring on the final dose distribution in the design of the Lung cancer intensity-modulated radiation therapy (IMRT) plan was studied. Materials and Methods: A total of 20 patients with Lung cancer in 2017 were selected. Seven radiation beams were designed for each patient, and the limit ring width (RW) was set at 0. 6, 0. 8, 1. 0, and 1. 2 cm, respectively. The distance between the inner diameter of the limit ring and the target area (RD) was set 0. 6, 0. 8, 1. 0, and 1. 2 cm, respectively. The other parameters used in the plan were set at the same position. In addition, the conformity index (CI) and homogeneity index (HI) were calculated, and normal tissues were assessed. Results: Under the condition of the same number of radiation beams and the same distance between the limit ring and the target area, the smaller the limit ring, the better the CI of the target area and the less the HI of the target area. When the size of the limit ring was set the same, the closer the limit ring was to the target area, the better the CI of the dose in the target area, and the less the HI of the target area. Conclusions: In central Lung cancer, when the target volume is approximately 800 cc, the optimal dose distribution is obtained when the RW is set at 0. 8 cm and the RD is set at 0. 6 cm.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    FAN, Y., Qiu, G., PAN, Q., ZHANG, F., & Luan, S.. (2020). Technical note: A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 18(1), 185-189. SID. https://sid.ir/paper/759844/en

    Vancouver: Copy

    FAN Y., Qiu G., PAN Q., ZHANG F., Luan S.. Technical note: A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer. INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2020;18(1):185-189. Available from: https://sid.ir/paper/759844/en

    IEEE: Copy

    Y. FAN, G. Qiu, Q. PAN, F. ZHANG, and S. Luan, “Technical note: A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer,” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 18, no. 1, pp. 185–189, 2020, [Online]. Available: https://sid.ir/paper/759844/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button