مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

105
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

140
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling

Pages

  32-38

Abstract

 Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo Simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm, patient bore with of radius of 175 mm, which is compatible with brain size. In second design, cylindrical geometry was simulated with transaxial FOV and ring radius of 175 mm as well. Photon detection efficiency (PDE), NEMA line source sensitivity, Spatial resolution and Derenzo phantom image quality were analyzed. Results: We obtained PDE about 21. 7% versus 23. 8% in 250-750 keV and 19. 5% versus 21. 3% in 410-613 keV for point source in center of FOV for spheroid and cylindrical PET respectively. The results of NEMA sensitivity measurements indicate 3. 29 kcps/MBq versus 3. 64 kcps/MBq for spheroid and cylindrical designs. The Spatial resolution (FWHM) calculations using MLEM reconstruction algorithm show around 1. 6 mm for transvers and axial resolution for point source placed in center of FOV for both scanners. Also we found for spheroid and cylindrical designs 4. 8 and 2. 7 mm versus 4 and 3. 6 mm as transvers and axial mean resolution for off-center point sources. Conclusion: Performance evaluation study indicates that the spheroid geometry delivers better axial resolution whereas cylindrical design can still provide higher sensitivity and transvers Spatial resolution than the spheroid geometry PET with same scanner bore size.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Sheikhzadeh, Peyman, GHADIRI, HOSSEIN, GERAMIFAR, PARHAM, GHAFARIAN, PARDIS, & AY, MOHAMMAD REZA. (2019). Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling. IRANIAN JOURNAL OF NUCLEAR MEDICINE, 27(1 (SERIAL NUMBER 52)), 32-38. SID. https://sid.ir/paper/762114/en

    Vancouver: Copy

    Sheikhzadeh Peyman, GHADIRI HOSSEIN, GERAMIFAR PARHAM, GHAFARIAN PARDIS, AY MOHAMMAD REZA. Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling. IRANIAN JOURNAL OF NUCLEAR MEDICINE[Internet]. 2019;27(1 (SERIAL NUMBER 52)):32-38. Available from: https://sid.ir/paper/762114/en

    IEEE: Copy

    Peyman Sheikhzadeh, HOSSEIN GHADIRI, PARHAM GERAMIFAR, PARDIS GHAFARIAN, and MOHAMMAD REZA AY, “Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling,” IRANIAN JOURNAL OF NUCLEAR MEDICINE, vol. 27, no. 1 (SERIAL NUMBER 52), pp. 32–38, 2019, [Online]. Available: https://sid.ir/paper/762114/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button