Title

Technical note: Quality control of radiochemical purity and safety of 99mTc-HDP and 99mTc-phytate adiopharmaceuticals labeling

Pages

  179-181

Abstract

 Background: The use of various types of radioactive drugs has increased the usefulness of nuclear medicine. The efficiency of the labeling radioactive isotope 99mTc is crucial for the accuracy and reliability of an examination. We conducted a survey on the Quality control (QC) of radioactive isotopes (RI) by measuring their purity. Materials and Methods: The QC (always or necessary) of radiopharmaceuticals was confirmed in 12 medical institutions in a metropolitan area. The radiochemical purity (RCP) of 99mTc-HDP and 99mTcphytate was determined based on the measured radionuclide purity of 99mTc containing 99Mo. In addition, the effect of time after labeling and time after elution was analyzed. Results: None of the 12 hospitals regularly performed QC, and five hospitals administered QC when necessary. The average of 30 measurements of the 99Mo content in 99mTc from three manufacturers was 0. 0109 for A, 0. 0121 for B, and 0. 0114 for C. The average labeling efficiency was 96. 02% for 99mTc-HDP and 94. 97% for 99mTc-phytate after labeling. The labeling efficiency of 99mTc-HDP with different times after elution was 97. 56%, 95. 41%, 94. 86%, 93. 76%, and 91. 89% after 0. 5, 2, 4, 6, and 8 h, respectively, and that for 99mTc-phytate was 97. 21%, 97. 21%, 94. 42%, 93. 35%, and 89. 91% after 0. 5, 2, 4, 6, and 8 h, respectively. Conclusion: We analyzed the degree of maintenance needed for labeling efficiency. The degree of change should be provided to the clinical practitioner as basic data for the QC of the radiopharmaceutical.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Jeon, Y.H., Cho, Y.H., JUNG, J.H., & CHOI, J.H.. (2020). Technical note: Quality control of radiochemical purity and safety of 99mTc-HDP and 99mTc-phytate adiopharmaceuticals labeling. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 18(1), 179-181. SID. https://sid.ir/paper/768449/en

    Vancouver: Copy

    Jeon Y.H., Cho Y.H., JUNG J.H., CHOI J.H.. Technical note: Quality control of radiochemical purity and safety of 99mTc-HDP and 99mTc-phytate adiopharmaceuticals labeling. INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2020;18(1):179-181. Available from: https://sid.ir/paper/768449/en

    IEEE: Copy

    Y.H. Jeon, Y.H. Cho, J.H. JUNG, and J.H. CHOI, “Technical note: Quality control of radiochemical purity and safety of 99mTc-HDP and 99mTc-phytate adiopharmaceuticals labeling,” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 18, no. 1, pp. 179–181, 2020, [Online]. Available: https://sid.ir/paper/768449/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button