مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

882
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE IMPACT OF BREAST SIZE ON HEART AND LUNG DOSES IN THE TREATMENT OF BREAST CANCER USING 2 AND 3 DIMENSIONAL TANGENTIAL FIELDS

Pages

  758-764

Abstract

 Introduction: one of the important points in breast radiotherapy is uniform dose distribution with full coverage of the target volume and protection of critical organs. Size and shape of breast is effective on dose distribution of the target volume and critical organ dose. The aim of this study is to evaluate lung and HEART DOSEs in tangential fields in two and three-dimensional plans at different sizes of breast.Method and Materials: In this study, an anatomical phantom layer with lung heterogeneity in both small and large BREAST SIZEs was used. Body and cardiac were made of transparent and colored Plexiglas, respectively. Energy 6MV of linear accelerator was utilized for radiation. To obtain the volumes of the heart and lungs that have been received exceeded dose, the histogram dose - volume calculated by the conventional and three dimensional techniques were used. Common treatment method was implemented by means of manual counter and treatment planning software of RT Dose Plan was used for three-dimensional method.Results: in 3D way, the volumes of the lung and heart receiving dose exceeded than the conventional method which in lungs this was 7% for small BREAST SIZE and 24% for large breast. Also increased heart volumes for small and large BREAST SIZE are the 8.25% and 70% respectively.Conclusion: Based on the results of this study, although three-dimensional treatment planning is used to coverage the entire target volume, this can lead to increasing receiving dose in critical organs. Besides, larger breasts raise the possibility of higher dose in heart and lungs.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    AFKHAMI ARDAKANI, MAHDIEH, PARWAEI, WRYA, & HAGHPARAST, MOHAMAD. (2015). THE IMPACT OF BREAST SIZE ON HEART AND LUNG DOSES IN THE TREATMENT OF BREAST CANCER USING 2 AND 3 DIMENSIONAL TANGENTIAL FIELDS. JOURNAL OF SABZEVAR UNIVERSITY OF MEDICAL SCIENCES, 22(5), 758-764. SID. https://sid.ir/paper/81866/en

    Vancouver: Copy

    AFKHAMI ARDAKANI MAHDIEH, PARWAEI WRYA, HAGHPARAST MOHAMAD. THE IMPACT OF BREAST SIZE ON HEART AND LUNG DOSES IN THE TREATMENT OF BREAST CANCER USING 2 AND 3 DIMENSIONAL TANGENTIAL FIELDS. JOURNAL OF SABZEVAR UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2015;22(5):758-764. Available from: https://sid.ir/paper/81866/en

    IEEE: Copy

    MAHDIEH AFKHAMI ARDAKANI, WRYA PARWAEI, and MOHAMAD HAGHPARAST, “THE IMPACT OF BREAST SIZE ON HEART AND LUNG DOSES IN THE TREATMENT OF BREAST CANCER USING 2 AND 3 DIMENSIONAL TANGENTIAL FIELDS,” JOURNAL OF SABZEVAR UNIVERSITY OF MEDICAL SCIENCES, vol. 22, no. 5, pp. 758–764, 2015, [Online]. Available: https://sid.ir/paper/81866/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button