مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,496
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SHORT-TERM RESULTS OF OPEN WEDGE HIGH TIBIAL OSTEOTOMY USING T-BUTTRESS PLATE AND A METAL WEDGE

Pages

  102-108

Keywords

Abstract

 Background: High TIBIA OSTEOTOMY remains an acceptable method for prevention of medial comportment knee osteoarthritis. The conventional technique is a closing wedge OSTEOTOMY. We planned to study short-term results of a medial open wedge high TIBIA OSTEOTOMY using T-Buttress plate and a metal wedge.Methods: In this case series study, 60 patients (76 knees, 27 male and 33 female) underwent an open wedge high TIBIA OSTEOTOMY surgery using a T-Buttress plate and a metal wedge in a in a teaching hospital in Kerman-Iran. Patients were assessed clinically and radiographically including Modified Hospital for Special Surgery Knee Scoring System (HSSKS), anatomical and mechanical limb alignment, Insall Salvati patellar height index and proximal TIBIA posterior slope angle.Results: The mean TIBIA-femoral angle changed from -6.8 to +4.33 degrees. 26(43.3%) patients needed iliac cancellous graft. The mean metal wedge size was 11.07 mm (8-15 mm). The mean Modified HSSKS promoted from 75.5 to 98.73. The observed complications were: fracture in five, intraarticular screw penetration in four (one in proximal TIBIA-fibular joint), infection in two and under-correction in one patient. There was no non-union, proneal nerve injury, over-correction, plate failure, deep vein thrombosis and bone graft donor site complication. The mean posterior TIBIA slope changed from 8.05±1.95 to 8.68±1.54 degrees and patellar height index changed from 1.06 to. 97.Conclusion: This procedure is a safe and reliable technique and lessened the need for an autograft. Significant improvement in score of Modified HSSKS was seen post operatively.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KARIMI MOBARAKEH, MAHMOOD, MARDANI KIVI, MOHSEN, KEYHANI, SOHRAB, & SAFAEE, HADI. (2011). SHORT-TERM RESULTS OF OPEN WEDGE HIGH TIBIAL OSTEOTOMY USING T-BUTTRESS PLATE AND A METAL WEDGE. IRANIAN JOURNAL OF ORTHOPAEDIC SURGERY, 9(3 (36)), 102-108. SID. https://sid.ir/paper/85456/en

    Vancouver: Copy

    KARIMI MOBARAKEH MAHMOOD, MARDANI KIVI MOHSEN, KEYHANI SOHRAB, SAFAEE HADI. SHORT-TERM RESULTS OF OPEN WEDGE HIGH TIBIAL OSTEOTOMY USING T-BUTTRESS PLATE AND A METAL WEDGE. IRANIAN JOURNAL OF ORTHOPAEDIC SURGERY[Internet]. 2011;9(3 (36)):102-108. Available from: https://sid.ir/paper/85456/en

    IEEE: Copy

    MAHMOOD KARIMI MOBARAKEH, MOHSEN MARDANI KIVI, SOHRAB KEYHANI, and HADI SAFAEE, “SHORT-TERM RESULTS OF OPEN WEDGE HIGH TIBIAL OSTEOTOMY USING T-BUTTRESS PLATE AND A METAL WEDGE,” IRANIAN JOURNAL OF ORTHOPAEDIC SURGERY, vol. 9, no. 3 (36), pp. 102–108, 2011, [Online]. Available: https://sid.ir/paper/85456/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top