مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

734
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

GENERATING A HOMOGENEOUS DOSE DISTRIBUTION IN THE JUNCTION REGION BETWEEN TWO ADJACENT FIELDS IN ELECTRON BEAM THERAPY

Author(s)

 TAHMASEBI BIRGANI MOHAMMAD JAVAD | BEHROOZ MOHAMMAD ALI | KEIVAN HADI | Issue Writer Certificate 

Pages

  29-34

Abstract

 Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new method for generating a homogeneous dose distribution in the junction region between two adjacent fields in electron beam therapy.Materials and Methods: Several approaches have been proposed to solve the problem of ‘hot’ and ‘cold’ spots in the junction region between abutting electron fields. These techniques are based on beam-edge modifying devices or penumbra generators which act to broaden the electron beam penumbra, and thus facilitate field matching. But use of these devices is time consuming and design of the modifications to the applicators are generally applicator dependent. An idea which was originally proposed for matching two adjacent photon fields (with dose inhomogeneity of about %2) is resurrected here. This method is based on the rotation of the gantry such that the adjacent fields have a common edge and the overlap region in treatment volume is eliminated. For this purpose, the effective source to surface distance (SSDeff) for the available electron beam energies (6, 9, 12 and 15 MeV) and applicators (cones) (6×6, 10×10, 15×15, 20×20 and 25×25 cm2) have been determined for a Varian 2100C LINEAR ACCELERATOR.Result: Using SSDeff, in respect to beam divergence, one can use the photon beam behavior for electron beams and achieve a uniform dose distribution in ADJACENT ELECTRON FIELDS.Discussion and Conclusion: Compared to beam-edge modifying devices or penumbra generators that are usually time consuming to plan and set up, rotating the gantry to eliminate the overlap region is simple and applicable in the problem of abutting electron fields.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAHMASEBI BIRGANI, MOHAMMAD JAVAD, BEHROOZ, MOHAMMAD ALI, & KEIVAN, HADI. (2010). GENERATING A HOMOGENEOUS DOSE DISTRIBUTION IN THE JUNCTION REGION BETWEEN TWO ADJACENT FIELDS IN ELECTRON BEAM THERAPY. IRANIAN JOURNAL OF MEDICAL PHYSICS, 7(3 (28)), 29-34. SID. https://sid.ir/paper/96943/en

    Vancouver: Copy

    TAHMASEBI BIRGANI MOHAMMAD JAVAD, BEHROOZ MOHAMMAD ALI, KEIVAN HADI. GENERATING A HOMOGENEOUS DOSE DISTRIBUTION IN THE JUNCTION REGION BETWEEN TWO ADJACENT FIELDS IN ELECTRON BEAM THERAPY. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2010;7(3 (28)):29-34. Available from: https://sid.ir/paper/96943/en

    IEEE: Copy

    MOHAMMAD JAVAD TAHMASEBI BIRGANI, MOHAMMAD ALI BEHROOZ, and HADI KEIVAN, “GENERATING A HOMOGENEOUS DOSE DISTRIBUTION IN THE JUNCTION REGION BETWEEN TWO ADJACENT FIELDS IN ELECTRON BEAM THERAPY,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 7, no. 3 (28), pp. 29–34, 2010, [Online]. Available: https://sid.ir/paper/96943/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button