مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

865
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INVESTIGATION OF THE FIELD SIZE EFFECT ON WEDGE FIELD ISODOSE CURVES ANGLE FOR TWO ENERGIES; 6 & 18 MV, PRODUCED BY VARIAN 2100C LINAC

Pages

  35-42

Abstract

 Introduction: Nowadays, considerable developments in the field of radiotherapy have been achieved. They include the advances made in the equipments and treatment planning techniques which require highly complex calculations. Such achievements have made it possible to treat cancer patients not only with higher radiation dose but also with higher precision and consequently increasing the chance of curing the cancer. However, the conventional techniques requiring physical wedge are still being used but with a lesser frequency. One of the wedge parameters needed to be measured is the WEDGE ANGLE. It is the angle that the horizontal line creates with the tilted ISODOSE CURVE at a specific depth and for a certain field size.In this study, the variation of WEDGE ANGLE for different field sizes was evaluated using dosimetric and mathematical method.Material and Methods: For the wedge fields with a dimension of 6×6 to 20×20 cm2, the WEDGE ANGLE for two photon energies of 6 and 18 MV was measured by the dosimetric method. For these measurements, the conventional wedges having the nominal WEDGE ANGLE of 15, 30, 45 & 60 were used. The theoretical method suggested by Saw et al. is also used to indirectly calculate the slope of ISODOSE CURVE by the dose profile and percent depth dose data. The dose profile, percentage depth dose and ISODOSE CURVEs were drawn for all the field sizes and the tilt of ISODOSE CURVE at 10 cm depth, according to international definition, is considered as the WEDGE ANGLE. The data were obtained using the theoretical equation of WEDGE ANGLE and it was compared to the dosimetric data.Results: The result obtained in this work shows that the WEDGE ANGLE increases with the field size. For a 6×6 cm2 field size, the calculated WEDGE ANGLE has the highest difference in comparison to the nominal WEDGE ANGLE. The difference is equal to 14.7 degree for a 45o wedge and a 6 MV photon. The highest difference for a 45o WEDGE ANGLE, a field size of 10×10 cm2 and a 6 MV photon is 9.2 degree. Comparing the calculated and measured WEDGE ANGLEs shows a maximum difference of 4 degree for 6 and 18 MV photon beams.Discussion and Conclusion: The WEDGE ANGLE varies with field size. In order to get a better dose distribution in the conventional radiotherapy, it is necessary to use the appropriate WEDGE ANGLE which generates the desired slope for the isodose line and for the specific field size.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAHMASBI BEYRGANI, M.J., BEHROUZ, M.A., ARVANDI, SH., KHEZERLOU, D., & KARBALAEI, M.. (2008). INVESTIGATION OF THE FIELD SIZE EFFECT ON WEDGE FIELD ISODOSE CURVES ANGLE FOR TWO ENERGIES; 6 & 18 MV, PRODUCED BY VARIAN 2100C LINAC. IRANIAN JOURNAL OF MEDICAL PHYSICS, 5(1 (18-19)), 35-42. SID. https://sid.ir/paper/97015/en

    Vancouver: Copy

    TAHMASBI BEYRGANI M.J., BEHROUZ M.A., ARVANDI SH., KHEZERLOU D., KARBALAEI M.. INVESTIGATION OF THE FIELD SIZE EFFECT ON WEDGE FIELD ISODOSE CURVES ANGLE FOR TWO ENERGIES; 6 & 18 MV, PRODUCED BY VARIAN 2100C LINAC. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2008;5(1 (18-19)):35-42. Available from: https://sid.ir/paper/97015/en

    IEEE: Copy

    M.J. TAHMASBI BEYRGANI, M.A. BEHROUZ, SH. ARVANDI, D. KHEZERLOU, and M. KARBALAEI, “INVESTIGATION OF THE FIELD SIZE EFFECT ON WEDGE FIELD ISODOSE CURVES ANGLE FOR TWO ENERGIES; 6 & 18 MV, PRODUCED BY VARIAN 2100C LINAC,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 5, no. 1 (18-19), pp. 35–42, 2008, [Online]. Available: https://sid.ir/paper/97015/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button