مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

4,767
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

DISTRIBUTION SURVEY OF ELECTRIC AND MAGNETIC FIELD INTENSITY AT A HIGH VOLTAGE ELECTRICITY POST IN ZANJAN CITY USING GIS TECHNOLOGY

Pages

  379-386

Abstract

 Background and Objectives: ELECTRIC AND MAGNETIC FIELDS in the workplace are one of the detrimental factors of power plants, transmission lines, electrical wires, and electrical equipments, therefore, exposure to these fields might be harmful for human health. This study aimed to provide information about intensity of the electromagnetic fields at the HIGH VOLTAGE ELECTRICITY POSTs and its comparison with the threshold limit value (TLV).Materials and Methods: The study was conducted at one of the HIGH VOLTAGE ELECTRICITY POST in Zanjan City having 63, 230, and 400 KV power transmission lines. After identifying stations and measuring the intensity of these fields, GIS maps were prepared and the values were compared with permissible values.Results: The measured magnetic flux density at different parts of the high voltage post showed that the lowest and highest intensity were 1.69 and 153.7 mG respectively which were lower than the ACGIH TLVs.The lowest and highest intensity of the electric field were 0.008 and 38.07 KV/m respectively. The highest value belonged to the 400 KV line, which exceeds the recommended ACGIH TLV (25 KV/m).Conclusion: According to the results, the magnetic field intensity was below the TLVs, but the intensity of electric field measured in the 400 KV line was greater than its TLVs. Thus, the strategies and recommendations for reducing exposure should be taken.

Cites

References

  • No record.
  • Cite

    APA: Copy

    MAJIDI, FARAMARZ, ALAVI, SOMAIEH, AZIMI PIRSARAEI, REZA, HEIDARY, ABDOLLAH, & ASGARI, FARHAD. (2012). DISTRIBUTION SURVEY OF ELECTRIC AND MAGNETIC FIELD INTENSITY AT A HIGH VOLTAGE ELECTRICITY POST IN ZANJAN CITY USING GIS TECHNOLOGY. IRANIAN JOURNAL OF HEALTH AND ENVIRONMENT, 5(3 (17)), 379-386. SID. https://sid.ir/paper/145714/en

    Vancouver: Copy

    MAJIDI FARAMARZ, ALAVI SOMAIEH, AZIMI PIRSARAEI REZA, HEIDARY ABDOLLAH, ASGARI FARHAD. DISTRIBUTION SURVEY OF ELECTRIC AND MAGNETIC FIELD INTENSITY AT A HIGH VOLTAGE ELECTRICITY POST IN ZANJAN CITY USING GIS TECHNOLOGY. IRANIAN JOURNAL OF HEALTH AND ENVIRONMENT[Internet]. 2012;5(3 (17)):379-386. Available from: https://sid.ir/paper/145714/en

    IEEE: Copy

    FARAMARZ MAJIDI, SOMAIEH ALAVI, REZA AZIMI PIRSARAEI, ABDOLLAH HEIDARY, and FARHAD ASGARI, “DISTRIBUTION SURVEY OF ELECTRIC AND MAGNETIC FIELD INTENSITY AT A HIGH VOLTAGE ELECTRICITY POST IN ZANJAN CITY USING GIS TECHNOLOGY,” IRANIAN JOURNAL OF HEALTH AND ENVIRONMENT, vol. 5, no. 3 (17), pp. 379–386, 2012, [Online]. Available: https://sid.ir/paper/145714/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button