مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

3,860
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

HAZARD IDENTIFICATION AND RISK ASSESSMENT OF HIGH VOLTAGE POWER LINES IN RESIDENTIAL AREAS USING FAILURE MODES AND EFFECTS ANALYSIS (FMEA)

Pages

  55-64

Abstract

 Background: FMEA is one of the best known system safety techniques widely used as an identification tool. The purpose of this study was to apply FMEA method to identify and assess the risks posed by power lines in a residential area is Hasyrabad, AHWAZ.Materials and Methods: First, we identified the power line process and the equipment involved. Later, we determined the failure modes of equipment, which leads to the risk in the area studied. In order to measure the magnetic field lines, we used 3D EMF TESTER. Risks identified were scored based on the FMEA and for each case we calculated RPN. Then, with the help of SPSS software, we calculated level of risk and the cases identified were prioritized and analyzed based on the risk level.Results: The highest RPN values were associated with health risks and all risks involved in this group are at emergency conditions. It was revealed that wires (loss of privacy) and POWER TRANSMISSION LINE (non-compliance with privacy standards) had highest value (RPN 360) and disconnect switch had lowest value (RPN 60).Conclusion: Due to the high risk in most cases, control measures were proposed based on the expertise in the safety-related equipment, training operators, and regulatory measures in order to reduce the level of risk.

Cites

References

Cite

APA: Copy

JOZI, A., JAFARZADEH HAGHIGHI FARD, N., & AFZALI BEHBAHANI, N.. (2014). HAZARD IDENTIFICATION AND RISK ASSESSMENT OF HIGH VOLTAGE POWER LINES IN RESIDENTIAL AREAS USING FAILURE MODES AND EFFECTS ANALYSIS (FMEA). IRANIAN JOURNAL OF HEALTH AND ENVIRONMENT, 7(1), 55-64. SID. https://sid.ir/paper/146063/en

Vancouver: Copy

JOZI A., JAFARZADEH HAGHIGHI FARD N., AFZALI BEHBAHANI N.. HAZARD IDENTIFICATION AND RISK ASSESSMENT OF HIGH VOLTAGE POWER LINES IN RESIDENTIAL AREAS USING FAILURE MODES AND EFFECTS ANALYSIS (FMEA). IRANIAN JOURNAL OF HEALTH AND ENVIRONMENT[Internet]. 2014;7(1):55-64. Available from: https://sid.ir/paper/146063/en

IEEE: Copy

A. JOZI, N. JAFARZADEH HAGHIGHI FARD, and N. AFZALI BEHBAHANI, “HAZARD IDENTIFICATION AND RISK ASSESSMENT OF HIGH VOLTAGE POWER LINES IN RESIDENTIAL AREAS USING FAILURE MODES AND EFFECTS ANALYSIS (FMEA),” IRANIAN JOURNAL OF HEALTH AND ENVIRONMENT, vol. 7, no. 1, pp. 55–64, 2014, [Online]. Available: https://sid.ir/paper/146063/en

Related Journal Papers

Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top