مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,224
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A REVIEW OF COMPUTER-AIDED DETECTION OF PULMONARY EMBOLISM IN CT ANGIOGRAMS

Pages

  223-232

Abstract

 Introduction: pulmonary COMPUTED TOMOGRAPHY ANGIOGRAPHY (CTA) is widely used in the detection of PULMONARY EMBOLISM. Using these thin slices for studying clinical function of lung is necessary, but it is time-consuming for radiologists. Therefore, several systems have been designed for detection of embolism. The aim of this study was to review and evaluate systems of detection of PULMONARY EMBOLISM.Methods: In this study, all the articles in databases including IEEE, Science Direct, Medical Physics and SPIE in the field of processing pulmonary computed tomography angiograms and computer-aided detection systems were reviewed. A total of 16 articles between 2002 and 2015 were extracted. Each article presented one CAD system that was evaluated with quantitative and qualitative analysis. To assess systems, the number of images in database, sensitivity and false positive error rate were used.Results: Various systems are designed to detect embolism. Image database is affected by different factors such as pulmonary diseases, noise, the time of taking image, diversity of PULMONARY EMBOLISM in main and peripheral branches and the number of data. The maximum number of data was 177 samples and the minimum was 3 samples. Sensitivity and the number of false positive errors are good criteria. Among the CAD systems, the sensitivity was 50% to 100% and the rate of false positive was 2- 22.6 per scan.Conclusion: According to the results, in addition to having high sensitivity and low false positive error, detection systems must have large image database of embolism in various branches of vessels.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Masoudi, Mojtaba, Pourreza, Hamidreza, SAADATMAND TARZJAN, MAHDI, SHAFIEE ZARGAR, FATEME, AMINI, MAHNAZ, & PEZESHKI RAD, MASOUD. (2016). A REVIEW OF COMPUTER-AIDED DETECTION OF PULMONARY EMBOLISM IN CT ANGIOGRAMS. JOURNAL OF HEALTH AND BIOMEDICAL INFORMATICS, 3(3), 223-232. SID. https://sid.ir/paper/258904/en

    Vancouver: Copy

    Masoudi Mojtaba, Pourreza Hamidreza, SAADATMAND TARZJAN MAHDI, SHAFIEE ZARGAR FATEME, AMINI MAHNAZ, PEZESHKI RAD MASOUD. A REVIEW OF COMPUTER-AIDED DETECTION OF PULMONARY EMBOLISM IN CT ANGIOGRAMS. JOURNAL OF HEALTH AND BIOMEDICAL INFORMATICS[Internet]. 2016;3(3):223-232. Available from: https://sid.ir/paper/258904/en

    IEEE: Copy

    Mojtaba Masoudi, Hamidreza Pourreza, MAHDI SAADATMAND TARZJAN, FATEME SHAFIEE ZARGAR, MAHNAZ AMINI, and MASOUD PEZESHKI RAD, “A REVIEW OF COMPUTER-AIDED DETECTION OF PULMONARY EMBOLISM IN CT ANGIOGRAMS,” JOURNAL OF HEALTH AND BIOMEDICAL INFORMATICS, vol. 3, no. 3, pp. 223–232, 2016, [Online]. Available: https://sid.ir/paper/258904/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button