مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

479
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

464
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARATIVE ANALYTICAL PERFORMANCE OF VARIOUS HBA1C ASSAYS IN IRAN

Pages

  414-419

Abstract

 INTRODUCTION: HEMOGLOBIN A1C (HbA1c) measurement devices are widely used to evaluate glycemic control in diabetic patients. The aim of this study was to investigate the comparability of various HbA1c instruments used in Iran.METHODS: In the present study, 154 fresh whole blood samples from diabetic patients, with different HbA1c levels (4.0%-10%) and no types of hemoglobinopathy were analyzed by six HbA1c assays including one high performance liquid chromatography (HPLC) method (D10 HbA1c), two immunoassay methods (COBAS INTEGRA 400 and Pars Azmoon kit), one Boronate affinity method (Nycocard Reader II), and two ion exchange methods (Biosystems and DS5). The two National Glycohemoglobin STANDARDIZATION Programs (NGSP) certified system, D10 and COBAS INTEGRA 400 which are certified as secondary reference measurement procedures, were considered as reference methods. The CLSI document (EP9-A2) - Method comparison and Bias estimation using patient samples, approved guideline - was used to compare the performance of different HbA1c instruments.RESULTS: The mean of HbA1c in all four types of assays was less than the reference methods (P-value <0.01).The mean of absolute difference between the reference methods was the least (0.11%). Among the other four tests, Biosystems had the smallest mean of difference (-0.21%), while Pars Azmoon had the highest (-1.18%). Pars Azmoon showed the greatest difference (95% confidence interval) when compared to D10 [-15.5%(-5.7%to -25.3%)] and COBAS INTEGRA [-17% (-9.16% to -24.84%)]. The highest regression slope (B) was found in DS5 method (0.96) in regression model with both reference methods.CONCLUSION: It can be concluded that although HbA1c STANDARDIZATION programs have resulted in great improvements in the comparability of HbA1c assays, unacceptable errors still exist and further national and international projects are required for STANDARDIZATION of HbA1c measurement. In this situation, it is recommended to use the same laboratory for HbA1c measurement to monitor diabetic patients.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    RAZI, FARIDEH, RAHNAMAYE FARZAMI, MARJAN, EBRAHIMI, SOLTAN AHMAD, NAHID, MEHRZAD, GHOLI BIGDELI, MOSTAFA, SHEIDAEI, ALI, GHASEMIAN, ANOOSHEH, TOOTEE, ALI, KERAMATI, TAHEREH, NASLI ESFAHANI, ENSIEH, LARIJANI, BAGHER, & PASALAR, PARVIN. (2016). COMPARATIVE ANALYTICAL PERFORMANCE OF VARIOUS HBA1C ASSAYS IN IRAN. ARCHIVES OF IRANIAN MEDICINE, 19(6), 414-419. SID. https://sid.ir/paper/281377/en

    Vancouver: Copy

    RAZI FARIDEH, RAHNAMAYE FARZAMI MARJAN, EBRAHIMI SOLTAN AHMAD, NAHID MEHRZAD, GHOLI BIGDELI MOSTAFA, SHEIDAEI ALI, GHASEMIAN ANOOSHEH, TOOTEE ALI, KERAMATI TAHEREH, NASLI ESFAHANI ENSIEH, LARIJANI BAGHER, PASALAR PARVIN. COMPARATIVE ANALYTICAL PERFORMANCE OF VARIOUS HBA1C ASSAYS IN IRAN. ARCHIVES OF IRANIAN MEDICINE[Internet]. 2016;19(6):414-419. Available from: https://sid.ir/paper/281377/en

    IEEE: Copy

    FARIDEH RAZI, MARJAN RAHNAMAYE FARZAMI, SOLTAN AHMAD EBRAHIMI, MEHRZAD NAHID, MOSTAFA GHOLI BIGDELI, ALI SHEIDAEI, ANOOSHEH GHASEMIAN, ALI TOOTEE, TAHEREH KERAMATI, ENSIEH NASLI ESFAHANI, BAGHER LARIJANI, and PARVIN PASALAR, “COMPARATIVE ANALYTICAL PERFORMANCE OF VARIOUS HBA1C ASSAYS IN IRAN,” ARCHIVES OF IRANIAN MEDICINE, vol. 19, no. 6, pp. 414–419, 2016, [Online]. Available: https://sid.ir/paper/281377/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button