Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

377
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

280
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

DOSE CALCULATIONS ACCURACY OF TIGRT TREATMENT PLANNING SYSTEM FOR SMALL IMRT BEAMLETS IN HETEROGENEOUS LUNG PHANTOM

Pages

  345-354

Abstract

 Background: Accurate dose calculations in SMALL BEAMLETS and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calculaon accuracy of TIGRT TPS was evaluated for SMALL BEAMLETS in water and lung phantom by comparison to Monte Carlo (MC) calculations.Materials and Methods: The head of Siemens Oncor-impression linac was simulated for 6 and 18 MV photon beams using MCNPX MC Code. The model was validated using measured percentage depth dose and beam profiles. Then, the validated model used for dose calculations for small beam lets in water as well as lung phantoms. For treatment planning purposes, the lung phantom was scanned and imported into the TPS, and then the percentage depth dose values were obtained from plans for small fields of 1×1, 2×2, 3×3 and 4×4 cm2 in water and lung phantom.Results: For small fields in water phantom, there was a good agreement between TPS and MC for 2×2 to 4×4 cm2 field sizes. Nevertheless, the depth doses in lung phantom showed large discrepancies between TPS and MC calculations for points inside lung and lung-so4 tissue interfaces. The TPS underesmated the lung dose up to 67% and 110% for 6 and 18 MV beams compared to MC results.Conclusion: Our findings revealed that the TIGRT TPS was not able to account for lung inhomogeies in SMALL BEAMLETS. Besides, the TPS calculated depth doses were not accurate enough to be used for SMALL BEAMLETS used in IMRT of lung region.

Cites

References

  • No record.
  • Cite

    APA: Copy

    MESBAHI, A., & DADGAR, H.. (2015). DOSE CALCULATIONS ACCURACY OF TIGRT TREATMENT PLANNING SYSTEM FOR SMALL IMRT BEAMLETS IN HETEROGENEOUS LUNG PHANTOM. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 13(4), 345-354. SID. https://sid.ir/paper/286689/en

    Vancouver: Copy

    MESBAHI A., DADGAR H.. DOSE CALCULATIONS ACCURACY OF TIGRT TREATMENT PLANNING SYSTEM FOR SMALL IMRT BEAMLETS IN HETEROGENEOUS LUNG PHANTOM. INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2015;13(4):345-354. Available from: https://sid.ir/paper/286689/en

    IEEE: Copy

    A. MESBAHI, and H. DADGAR, “DOSE CALCULATIONS ACCURACY OF TIGRT TREATMENT PLANNING SYSTEM FOR SMALL IMRT BEAMLETS IN HETEROGENEOUS LUNG PHANTOM,” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 13, no. 4, pp. 345–354, 2015, [Online]. Available: https://sid.ir/paper/286689/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top