مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

747
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF PRESCRIBED AND DELIVERED DOSE TO PATIENTS IN RADIOTHERAPY DEPARTMENT OF TABRIZ IMAM-KHOMEINI HOSPITAL USING IN VIVO DOSIMETRY

Pages

  103-107

Abstract

 Background and objectives: Accuracy of the delivered dose to the patient is one of the most important and effective factors in RADIOTHERAPY. IN VIVO DOSIMETRY is used to evaluate the accuracy of delivered dose in RADIOTHERAPY. Therefore, in this study the accuracy of delivered dose to the patients was verified using IN VIVO DOSIMETRY in RADIOTHERAPY department of Tabriz Imam Hospital.Materials and Methods: Entrance doses of 320 fields treated by Cobalt-60 machine and LINEAR ACCELERATOR including head and neck, trunk, pelvis, and extremities were measured using IN VIVO DOSIMETRY system. Difference between measured entrance dose and prescribed dose for each field was determined. For all fields and also for each specific group of fields, average error and standard deviation of its distribution were determined.Results: For whole fields, the average error of 1.34% with standard deviation (SD) of 7.12%, for 60Co fields the average error of -0.17% with SD of 5.98% and for Linac fields, the average error of -3.56% and 7.17% were seen. In head and neck fields, the average error of -0.37% with SD of 4.73%; for trunk fields the average error of %-1.88 with SD of 7.27%, and for pelvis and extremities, the average error of -2.49% with SD of 7.79% were seen.Conclusion: The results show an acceptable systematic error in RADIOTHERAPY department.But standard deviation of 7.12% is slightly higher than the recommended value of 5%. It is possible to lower the uncertainty in delivered dose to recommended value by optimization of Linac function, regular QUALITY CONTROL, and workload reduction.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MESBAHI, A., FARAJ ELAHI, A.R., SEYED OSKOIE, GH.R., & NASERI, A.R.. (2007). COMPARISON OF PRESCRIBED AND DELIVERED DOSE TO PATIENTS IN RADIOTHERAPY DEPARTMENT OF TABRIZ IMAM-KHOMEINI HOSPITAL USING IN VIVO DOSIMETRY. MEDICAL JOURNAL OF TABRIZ UNIVERSITY OF MEDICAL SCIENCES, 28(4), 103-107. SID. https://sid.ir/paper/46910/en

    Vancouver: Copy

    MESBAHI A., FARAJ ELAHI A.R., SEYED OSKOIE GH.R., NASERI A.R.. COMPARISON OF PRESCRIBED AND DELIVERED DOSE TO PATIENTS IN RADIOTHERAPY DEPARTMENT OF TABRIZ IMAM-KHOMEINI HOSPITAL USING IN VIVO DOSIMETRY. MEDICAL JOURNAL OF TABRIZ UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2007;28(4):103-107. Available from: https://sid.ir/paper/46910/en

    IEEE: Copy

    A. MESBAHI, A.R. FARAJ ELAHI, GH.R. SEYED OSKOIE, and A.R. NASERI, “COMPARISON OF PRESCRIBED AND DELIVERED DOSE TO PATIENTS IN RADIOTHERAPY DEPARTMENT OF TABRIZ IMAM-KHOMEINI HOSPITAL USING IN VIVO DOSIMETRY,” MEDICAL JOURNAL OF TABRIZ UNIVERSITY OF MEDICAL SCIENCES, vol. 28, no. 4, pp. 103–107, 2007, [Online]. Available: https://sid.ir/paper/46910/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button