مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

280
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

143
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INVESTIGATING THE EFFECTS OF CUT-OUT SHIELD ON HIGH-ENERGY ELECTRON FIELDS USING MAGIC NORMOXIC POLYMER GEL

Pages

  78-86

Abstract

 IntroductionThe use of cut-outs in ELECTRON applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and ELECTRON beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters.Materials and MethodsDosimetry was performed with and without a square SHIELD (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom was filled with MAGIC gel polymer. For each section, transverse relaxation rate (R2) maps were obtained from MRI images and percentage depth doses and isodose curves were plotted.ResultsAverage energy was 3.029 MeV for the energy of 4 MeV and 8.155 MeV for the energy of 9 MeV. Surface dose was higher in SHIELDed field compared with the open one (due to ELECTRON scattering between the phantom and lead) which increased with increasing of energy. In the open field, for energies equal to 4, 9, and 16 MeV, the surface dose was 6.40, 6.48, and 7.20 Gy and for the SHIELDed mode, they were 6.63, 7.04, and 7.31 Gy, respectively. Also error values showed less errors and higher accuracy on curves by increasing of energy.ConclusionInvestigation of an isodose pattern in the SHIELDed mode showed scattering due to the lead, which is on the applicator. Overall, the results of this study demonstrated the value and potential of this dosimetric method with respect to characteristics such as stability, responsiveness and specially ability to show three dimensional ELECTRON beam dose distribution.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ANSARI MEHR, HADIS, ARBABI, AZIM, ZAHMATKESH, MOHAMMAD HASAN, ALLAHVERDI, MAHMOOD, & BAGHERI, SAEIDEH. (2013). INVESTIGATING THE EFFECTS OF CUT-OUT SHIELD ON HIGH-ENERGY ELECTRON FIELDS USING MAGIC NORMOXIC POLYMER GEL. IRANIAN JOURNAL OF MEDICAL PHYSICS, 10(3), 78-86. SID. https://sid.ir/paper/631734/en

    Vancouver: Copy

    ANSARI MEHR HADIS, ARBABI AZIM, ZAHMATKESH MOHAMMAD HASAN, ALLAHVERDI MAHMOOD, BAGHERI SAEIDEH. INVESTIGATING THE EFFECTS OF CUT-OUT SHIELD ON HIGH-ENERGY ELECTRON FIELDS USING MAGIC NORMOXIC POLYMER GEL. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2013;10(3):78-86. Available from: https://sid.ir/paper/631734/en

    IEEE: Copy

    HADIS ANSARI MEHR, AZIM ARBABI, MOHAMMAD HASAN ZAHMATKESH, MAHMOOD ALLAHVERDI, and SAEIDEH BAGHERI, “INVESTIGATING THE EFFECTS OF CUT-OUT SHIELD ON HIGH-ENERGY ELECTRON FIELDS USING MAGIC NORMOXIC POLYMER GEL,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 10, no. 3, pp. 78–86, 2013, [Online]. Available: https://sid.ir/paper/631734/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button