مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

288
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

184
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A STUDY ON SLAB‐WOODEN DUST-SLAB PHANTOM FOR THE DEVELOPMENT OF THORAX PHANTOM

Pages

  71-77

Abstract

 Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab‐wooden dust (pine) ‐SP34 slab (SWS) heterogeneous phantom.Materials and Methods: The density of SP34 slab, wooden dust of pine, and thoracic region of 10 patients were calculated using computed tomography (CT) images. The depths of isodose lines were measured for 6 MV beam on the CT images of the chest, PHANTOM/fa?page=1&sort=1&ftyp=all&fgrp=all&fyrs=all" target="_blank"> SP34 slab phantom, and SWS phantom. Dose calculation was performed at the depths of 2, 13, and 21 cm in both phantoms. Furthermore, patient-specific quality assurance (QA) was implemented using both phantoms.Results: The mean densities of the lung, SP34 slabs, and wooden dust were 0.29, 0.99, and 0.27 gm/cc respectively. The mean depths of different isodose lines in the SWS phantom were found to be equivalent to those in actual patients. Furthermore, the percentage variation between the planned and measured doses was higher in the SWS phantom as compared to that in the SP34 phantom. Furthermore, the percentage variation between the planned and measured doses in patient‐specific QA was higher in the SWS phantom as compared to that in the SP34 phantom.Conclusion: As the findings indicated, the density and isodose depth profiles of the SWS phantom were equivalent to those of the actual thoracic region of human.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    DUBEY, SWATI, BAGDARE, PRIYUSHA, GHOSH, SANJAY KUMAR, GURJAR, OM PRAKASH, BHANDARI, VIRENDRA, GUPTA, KRISHNA LAL, & KARNAWAT, SAURABH. (2018). A STUDY ON SLAB?WOODEN DUST-SLAB PHANTOM FOR THE DEVELOPMENT OF THORAX PHANTOM. IRANIAN JOURNAL OF MEDICAL PHYSICS, 15(2), 71-77. SID. https://sid.ir/paper/714305/en

    Vancouver: Copy

    DUBEY SWATI, BAGDARE PRIYUSHA, GHOSH SANJAY KUMAR, GURJAR OM PRAKASH, BHANDARI VIRENDRA, GUPTA KRISHNA LAL, KARNAWAT SAURABH. A STUDY ON SLAB?WOODEN DUST-SLAB PHANTOM FOR THE DEVELOPMENT OF THORAX PHANTOM. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2018;15(2):71-77. Available from: https://sid.ir/paper/714305/en

    IEEE: Copy

    SWATI DUBEY, PRIYUSHA BAGDARE, SANJAY KUMAR GHOSH, OM PRAKASH GURJAR, VIRENDRA BHANDARI, KRISHNA LAL GUPTA, and SAURABH KARNAWAT, “A STUDY ON SLAB?WOODEN DUST-SLAB PHANTOM FOR THE DEVELOPMENT OF THORAX PHANTOM,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 15, no. 2, pp. 71–77, 2018, [Online]. Available: https://sid.ir/paper/714305/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button