مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

123
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

67
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings

Pages

  271-275

Abstract

 Statement of the Problem: One of the major concerns about all ceramic crowns is their fracture resistance. Purpose: The purpose of this in vitro study was to evaluate the effect of two marginal designs (shoulder 90° , shoulder 135° ) on the fracture resistance of Zirconia copings. Materials and Method: In this in vitro study, 20 brass dies were prepared using milling machine: 10 with 1mm width shoulder 90° marginal design and the other 10 with 1mm width shoulder 135° finish line design. Zirconia cores with 0. 5mm thickness and 30μ m cement space were fabricated on brass dies. The copings were cemented on the dies and fracture test was done using a universal testing machine. Data were analyzed using Mann-Whitney test. Results: The mean value of fracture resistance for shoulder 90° finish line design were 368. 3± 109. 4 N and for shoulder 135° finish line design were 518. 4± 115. 5 N. Data analysis revealed a statistically significant difference between groups (p< 0. 05). Conclusion: The results of this study showed that the finish line design of Zirconia copings influences their fracture resistance. A 135° shoulder finish line design can improve the fracture resistance of Zirconia crowns.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HASHEMI ARDAKANI, ZAHRA, Khorsandipour, Shahar, MOHAGHEGH, MINA, Ghoreishian, Seyed Ahmad, & Reza Khaledi, Amir Ali. (2019). The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings. JOURNAL OF DENTISTRY (SHIRAZ UNIVERSITY OF MEDICAL SCIENCES), 20(4), 271-275. SID. https://sid.ir/paper/741392/en

    Vancouver: Copy

    HASHEMI ARDAKANI ZAHRA, Khorsandipour Shahar, MOHAGHEGH MINA, Ghoreishian Seyed Ahmad, Reza Khaledi Amir Ali. The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings. JOURNAL OF DENTISTRY (SHIRAZ UNIVERSITY OF MEDICAL SCIENCES)[Internet]. 2019;20(4):271-275. Available from: https://sid.ir/paper/741392/en

    IEEE: Copy

    ZAHRA HASHEMI ARDAKANI, Shahar Khorsandipour, MINA MOHAGHEGH, Seyed Ahmad Ghoreishian, and Amir Ali Reza Khaledi, “The Effect of Finish Line Design on the Fracture Strength of Zirconia Copings,” JOURNAL OF DENTISTRY (SHIRAZ UNIVERSITY OF MEDICAL SCIENCES), vol. 20, no. 4, pp. 271–275, 2019, [Online]. Available: https://sid.ir/paper/741392/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button