مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

160
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

126
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Stability and Dynamics of Zygomaticomaxillary Complex Fracture Treated Using Non-resorbable and Resorbable 2-and 3-Point Miniplates, Under Physiological and Maximal Occlusal Loads: A Finite Element Analysis

Pages

  134-142

Keywords

Finite Element Analysis (FEA). 

Abstract

 Background: Given that zygoma fractures are the second most common facial trauma, knowledge of their treatments is of clinical value. Among these are fixation methods, which despite their importance are neglected in many aspects. Objectives: Therefore, for the first time in the literature, the present finite element analysis evaluated displacements and dynamics of the zygoma fixed using four 2-and 3-point resorbable and four non-resorbable plates under normal and maximal mastication loads. Methods: A maxillofacial CT scan of a man with linear fractures without severe displacements was used to model the zygoma and its adjacent bones. Seven combinations of resorbable and seven combinations of non-resorbable mini-plates 2mm thick were fixed on the zygoma (orbital rim, zygomaticomaxillary buttress [ZMB], and frontozygomatic [FZ]) using 6mm miniscrews. ZMB was fixed using an L-shaped 4-hole plate. The infraorbital rim was fixed with a curved 5-hole miniplate. The FZ suture area was fixed with a 4-hole miniplate. The model underwent 150N and 750N loads. Minimum and maximum displacements, rotational displacements, stresses, and strains of the zygoma models were calculated. Results: Non-resorbable fixation methods can yield much smaller stresses, strains, and displacements compared to resorbable fixations. Also the parameters were much smaller under the 150N load compared to the 750N load. The worst results belonged to the fixation of Rim and ZMB and the best results belonged to the fixation of ZMB-Rim, and especially FZ-ZMB, Rim-FZ, and FZ-ZMB-Rim. Conclusions: In patients with heavy masticatory forces, it is not recommended to use resorbable platesZygomatic fractures are the second most common facial injury, knowledge of their management is important. However, fixations methods, which are of importance are variable.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SARKARAT, FARZIN, KHOSRAVI, MARYAM, Kahali, Roozbeh, Pirhadi Rad, Amirparham, Ebrahimi, Sogand, & RAKHSHAN, VAHID. (2020). Stability and Dynamics of Zygomaticomaxillary Complex Fracture Treated Using Non-resorbable and Resorbable 2-and 3-Point Miniplates, Under Physiological and Maximal Occlusal Loads: A Finite Element Analysis. TRAUMA MONTHLY, 25(3), 134-142. SID. https://sid.ir/paper/753548/en

    Vancouver: Copy

    SARKARAT FARZIN, KHOSRAVI MARYAM, Kahali Roozbeh, Pirhadi Rad Amirparham, Ebrahimi Sogand, RAKHSHAN VAHID. Stability and Dynamics of Zygomaticomaxillary Complex Fracture Treated Using Non-resorbable and Resorbable 2-and 3-Point Miniplates, Under Physiological and Maximal Occlusal Loads: A Finite Element Analysis. TRAUMA MONTHLY[Internet]. 2020;25(3):134-142. Available from: https://sid.ir/paper/753548/en

    IEEE: Copy

    FARZIN SARKARAT, MARYAM KHOSRAVI, Roozbeh Kahali, Amirparham Pirhadi Rad, Sogand Ebrahimi, and VAHID RAKHSHAN, “Stability and Dynamics of Zygomaticomaxillary Complex Fracture Treated Using Non-resorbable and Resorbable 2-and 3-Point Miniplates, Under Physiological and Maximal Occlusal Loads: A Finite Element Analysis,” TRAUMA MONTHLY, vol. 25, no. 3, pp. 134–142, 2020, [Online]. Available: https://sid.ir/paper/753548/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button