مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,944
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF THE ACCURACY OF INTRAOCULAR PRESSURE MEASUREMENT WITH THREE TONOMETER; PULSAIR EASY EYE, TONOPEN AND GOLDMANN

Pages

  20-25

Abstract

 Introduction & Objective: The measurement of INTRAOCULAR PRESSURE (IOP) is very important not only in the diagnosis and management of glaucomatous conditions but also in any ophthalmologic examination. So this study was designed to compare the results of noncontact pulsair and tononpen tonometry with GOLDMANN known as gold standard method. Materials & Methods: In this cross sectional study on 150 patients after a complete ophthalmic examination; tonometry was performed with GOLDMANN (G), pulsair (P) and TONOPEN (T). Mean values obtained from the three methods and the difference between the first two methods and G were measured and with descriptive statistical methods, t tests and regression tests were analyzed.Results: Mean measured IOP with P was greater than G and T (P=0.03). Correlation coefficient between the 3 methods was acceptable (r2=0.71). Mean difference between P and G does not differs significantly from 0 (P=0.19), but this value between T and G differs significantly from 0 (P=0.02). Both T and P underestimate IOP in high ranges.Conclusion: Both T and P tonometry measures have acceptable accuracy in comparison with G, but in suspicious cases such as glaucoma or ocular hypertension G is better as a gold standard method.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SORKHABI, R., & KHATIBIAN, P.. (2010). COMPARISON OF THE ACCURACY OF INTRAOCULAR PRESSURE MEASUREMENT WITH THREE TONOMETER; PULSAIR EASY EYE, TONOPEN AND GOLDMANN. AVICENNA JOURNAL OF CLINICAL MEDICINE (SCIENTIFIC JOURNAL OF HAMADAN UNIVERSITY OF MEDICAL SCIENCES AND HEALTH SERVICES), 16(4 (SN 54)), 20-25. SID. https://sid.ir/paper/17819/en

    Vancouver: Copy

    SORKHABI R., KHATIBIAN P.. COMPARISON OF THE ACCURACY OF INTRAOCULAR PRESSURE MEASUREMENT WITH THREE TONOMETER; PULSAIR EASY EYE, TONOPEN AND GOLDMANN. AVICENNA JOURNAL OF CLINICAL MEDICINE (SCIENTIFIC JOURNAL OF HAMADAN UNIVERSITY OF MEDICAL SCIENCES AND HEALTH SERVICES)[Internet]. 2010;16(4 (SN 54)):20-25. Available from: https://sid.ir/paper/17819/en

    IEEE: Copy

    R. SORKHABI, and P. KHATIBIAN, “COMPARISON OF THE ACCURACY OF INTRAOCULAR PRESSURE MEASUREMENT WITH THREE TONOMETER; PULSAIR EASY EYE, TONOPEN AND GOLDMANN,” AVICENNA JOURNAL OF CLINICAL MEDICINE (SCIENTIFIC JOURNAL OF HAMADAN UNIVERSITY OF MEDICAL SCIENCES AND HEALTH SERVICES), vol. 16, no. 4 (SN 54), pp. 20–25, 2010, [Online]. Available: https://sid.ir/paper/17819/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button