مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,019
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DETERMINATION OF SONOGRAPHIC DIAGNOSTIC ACCURACY IN BLUNT ABDOMINAL TRAUMA, 2003

Pages

  35-41

Abstract

 Background & Objectives: Patients in unstable condition with BLUNT ABDOMINAL TRAUMA require rapid evaluation of abdominal organs to assess the need for laparatomy. ULTRASONOGRAPHY is a fast technique which can be used in the resuscitation area to detect FREE INTRAPERITONEAL FLUID as an indication of intraabdominal injury. This prospective study was designed to determine the efficiency of emergency abdominal sonography for evaluating patients with BLUNT ABDOMINAL TRAUMA and to compare the accrurcy of ULTRASONOGRAPHY with the results of diagnostic peritoneal lavage and CT scan.Methods: Emergency sonography was performed prior to diagnostic peritoneal lavage and CT scan on 174 patients with blunt abdorminal trauma. Sonography was performed with FAST (Focused Abdominal Sonography for Trauma) technique and six area of the abdomen where examined to detect FREE INTRAPERITONEAL FLUID. Results: The results of this study revealed that ULTRASONOGRAPHY has a sensitivity of 95% a specificity of 80.8%., and an overall accuracy of 89.4% for detecting FREE INTRAPERITONEAL FLUID. The positive and negative predictive value of sonography was 89.4% and 90.1% respectively.Conclusion: ULTRASONOGRAPHY is a reliable method for the emergent evaluation of BLUNT ABDOMINAL TRAUMA and can be used instead of diagnostic peritoneal lavage.  

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HAMEDBARGHI, GH.A., MOHAMMADI, A., & SAFAEIAN, A.. (2005). DETERMINATION OF SONOGRAPHIC DIAGNOSTIC ACCURACY IN BLUNT ABDOMINAL TRAUMA, 2003. JOURNAL OF ARDABIL UNIVERSITY OF MEDICAL SCIENCES (JAUMS), 5(15), 35-41. SID. https://sid.ir/paper/59820/en

    Vancouver: Copy

    HAMEDBARGHI GH.A., MOHAMMADI A., SAFAEIAN A.. DETERMINATION OF SONOGRAPHIC DIAGNOSTIC ACCURACY IN BLUNT ABDOMINAL TRAUMA, 2003. JOURNAL OF ARDABIL UNIVERSITY OF MEDICAL SCIENCES (JAUMS)[Internet]. 2005;5(15):35-41. Available from: https://sid.ir/paper/59820/en

    IEEE: Copy

    GH.A. HAMEDBARGHI, A. MOHAMMADI, and A. SAFAEIAN, “DETERMINATION OF SONOGRAPHIC DIAGNOSTIC ACCURACY IN BLUNT ABDOMINAL TRAUMA, 2003,” JOURNAL OF ARDABIL UNIVERSITY OF MEDICAL SCIENCES (JAUMS), vol. 5, no. 15, pp. 35–41, 2005, [Online]. Available: https://sid.ir/paper/59820/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button