مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

3,500
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE COMPARISON OF PETCO2 OBTAINED FROM THE DISTAL AND PROXIMAL END OF ENDOTRACHEAL TUBE BY PACO2 IN CHILDREN VENTILATED BY MODIFIED JACKSON REES SYSTEM

Pages

  26-32

Abstract

 Capnography is one of the most important monitoring that is recommended by American Society for Testing and Material in 1998 (ASTM98) for every patient under anesthesia.Usually sampling of expired gas in capnography commonly obtained from side or mid stream. Badgwell and et al recommended that sampling of expired gas for Capnography for patient under one year should be taken from distal end of endotracheal tube.In this study to determine accuracy of ventilation with modified Jackson Rees system, we studied 622 infants and children who were ventilated with this system. Expired gas for CO2 monitoring sampled at distal and proximal end of endotracheal tube and the arterial Pco2 (PaCO2) simultaneously measured.In this paper we studied the accuracy of ventilation with modified Jackson Rees system in 62 infants and children. We sampled the expired gas for CO2 analysis from both proximal and distal of the endotracheal tube and measured PaCO2 simultaneously.In our experience we found that PETCO2-D (distal end - tidal PCO2) was close to PaCO2, but PETCO2-p(proximal end - tidal PCO2) was insignificantly greater than PaCO2 especialy in infant who were less than 10kg. As we did not find any significant difference between measurement of PETCO2-D (distal end tidal PCO2) and PETCO2-P (proximal end tidal PC02), we suggest to measure PETC02-p instead of PETC02-d, in any infant less than 10kg and children weighting more than 10kg who Ventilated by modified Jackson Rees system.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SOLTANI, A. A., GHAZI SAEIDI, KOBRA, & KHAJAVI, M.. (2002). THE COMPARISON OF PETCO2 OBTAINED FROM THE DISTAL AND PROXIMAL END OF ENDOTRACHEAL TUBE BY PACO2 IN CHILDREN VENTILATED BY MODIFIED JACKSON REES SYSTEM. JOURNAL OF IRANIAN SOCIETY ANAESTHESIOLOGY AND INTENSIVE CARE, 22(39), 26-32. SID. https://sid.ir/paper/63381/en

    Vancouver: Copy

    SOLTANI A. A., GHAZI SAEIDI KOBRA, KHAJAVI M.. THE COMPARISON OF PETCO2 OBTAINED FROM THE DISTAL AND PROXIMAL END OF ENDOTRACHEAL TUBE BY PACO2 IN CHILDREN VENTILATED BY MODIFIED JACKSON REES SYSTEM. JOURNAL OF IRANIAN SOCIETY ANAESTHESIOLOGY AND INTENSIVE CARE[Internet]. 2002;22(39):26-32. Available from: https://sid.ir/paper/63381/en

    IEEE: Copy

    A. A. SOLTANI, KOBRA GHAZI SAEIDI, and M. KHAJAVI, “THE COMPARISON OF PETCO2 OBTAINED FROM THE DISTAL AND PROXIMAL END OF ENDOTRACHEAL TUBE BY PACO2 IN CHILDREN VENTILATED BY MODIFIED JACKSON REES SYSTEM,” JOURNAL OF IRANIAN SOCIETY ANAESTHESIOLOGY AND INTENSIVE CARE, vol. 22, no. 39, pp. 26–32, 2002, [Online]. Available: https://sid.ir/paper/63381/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button